Docman GP 288 - December 2026

Training & Knowledge Updated by Training & Knowledge

Release 288 Release Notes - December 2026

This page contains details of new and amended functionality included in the software update scheduled for December 2026, known as Release 288.

Information Only - Introduce MESH Mailbox collections into Docman workflow keeping document management in one place

(Internal Reference GDWD-112 & 113 & 114 & 115 & 116)

This feature is not yet “switched on”, so users will not be able to activate it from this release, a pilot is required before this is generally available.

What have we done?

Introduced secondary care MESH correspondence into the Docman GP Workflow.

Why have we done this?

General Practices can now receive secondary care MESH correspondence directly into their central GP Document Workflow, eliminating split in-trays and unmanaged clinical document queues.

How will you benefit?

Secondary care hospitals may send discharge summaries and clinical letters via the NHS England MESH network straight into clinical systems, bypassing GP Document Workflow. For GP practice managers and clinical administrative teams who rely on GP Document Workflow as their governed front door, this creates dual in-trays, fragmented triage queues, and operational blind spots. Practice staff spend time checking multiple systems.

Details of the change

GP practices receive a single-inbox correspondence workflow. Practice staff continue using their familiar triage, workflow, and coding tools in GP Document Workflow.

Recognition of task value and units during coding task on TIF document

(Internal Reference GDWD-44/D10-17328)

What have we done?

Remediated an issue in the OCR process of TIF documents which failed to automatically recognise values and their unit type when there was no space – e.g. “Weight 53KG” was not being recognised, whereas “Weight 53 KG” was being recognised.

Why have we done this?

So that all valid values and the unit type are highlighted during coding, and are easily recognised and selected by the User during coding.

How will you benefit?

Manual value entry overhead is eliminated for concatenated unit document coding scenarios.

Details of the change

OCR process for TIF documents amended.

Scotland - Rehomer Tool (Orphan Docs): not moving potential Orphan Docs as expected

(Internal Reference GDWD-32/D10-17067)

What have we done?

Fixed an issue with the Rehomer tool, where it was attempting to pull orphan documents from invalid/incorrect locations.  Enhancements have also been made to the completion status information provided to the user, to show number of successful documents and number of failures.

Why have we done this?

The Rehomer tool for Orphan Documents was not moving all files into the correct folder and the status information was minimal

How will you benefit?

All “Orphan Documents” will be moved successfully

Details of the change

Rehomer tool software update

Scotland - Folders missing unique GUID

(Internal Reference GDWD-100/D10-17376)

What have we done?

Any documents which cannot be mapped to a standard folder at the point of migration from DM7 to DM10 will be added to the base folder in DM10.

Why have we done this?

During GP2GP patient record transfers from Docman 7 to Docman 10 in Scotland, documents associated with non-standard legacy folders cause dynamic folder creation in Docman 10 without an assigned external GUID. These GUID-less folders cause downstream SCI Gateway document ingestion and routing failures, blocking clinical document processing for Scotland practices.

How will you benefit?

All folders will have the unique GUID, removing any errors associated with GUID-less folders.

Details of the change

Software process has been updated.

Scotland – Migrate Pre Defined Messages and Replies from DM7 to DM10

(Internal Reference GDWD-101/ D10-16757)

What have we done?

Included predefined messages and replies in the migration from Docman 7 to  Docman 10..

Why have we done this?

To remediate a reported defect

How will you benefit?

Pre Defined messages and replies in DM7 will be migrated to DM10

Details of the change

Updated the Migration Service

Scotland Defect 1558: Enhancement to accept MOD10 CHI numbers

(Internal Reference GDWD-121/D10-17168)

What have we done?

Extended validation of CHI numbers to include Mod10 checks, as well as the current Mod11 checks.

Why have we done this?

NHS Scotland is transitioning Community Health Index (CHI) number generation from legacy Modulus 11 (MOD11) check-digit validation to Modulus 10 (MOD10). How will you benefit?

Docman 10 will support both Mod10 and Mod11 checks for Scotland

Details of the change

DM10 Web API software change

Scotland - Previous matching codes displaying code filing date not event date 

(Internal Reference GDWD-99/D10-17247)  

What have we done? 

Remediated a bug in the “Add Clinical Codes” function in Docman 10, which was using the system filing date in Vision rather than the Clinical event date 

Why have we done this? 

Accuracy in line with the Vision Clinical System 

How will you benefit? 

Eliminate clinical confusion and time to cross check the systems. 

Details of the change 

Software change in Docman 10

Security Improvements 

What have we done? 

Patching important security fixes and improvements  

Why have we done this? 

To ensure that the system has the latest security  

How will you benefit? 

Protection from known vulnerabilities 

Details of the change 

Patching important security fixes on backend services that support: 

  • Docman 10 – including SCI Gateway/OCR/Web App/Web API 
  • Docman Connect 

Platform Stability Update 

(Internal Reference CDTD-17)  

What have we done? 

 We have completed a behind-the-scenes update to one of our back-end components, restoring it to a previously stable version and putting it through full testing. 

Why have we done this? 

 A recent change to this component caused an issue, so we returned it to the earlier stable version to protect service quality. Before making further changes, we needed to review and rebuild the underlying code and test it thoroughly. 

How will you benefit? 

There is no change to the service you use today. This work means we can deliver future improvements to this component more smoothly, in the same way as the rest of our platform. 

Details of the change 

The code review, rebuild and full testing have confirmed that the component performs as expected. No action is needed on your part. 

How did we do?

Docman GP 286 - November 2026